OTHER TOPICS | Emergency Preparedness

Redundancy Is Resilience: Emergency Preparedness for Lift Stations

Preparing lift stations for severe weather events.

David Perry | Thompson Pump & Manufacturing Company

Hurricane season began on June 1, and municipalities and consulting engineers are once again evaluating the best methods to prepare their infrastructure for emergency events. While early forecasts suggest a near- to below-normal season, elevated sea surface temperatures could generate a single storm with the potential to cause widespread damaging impacts throughout a wastewater collection system. Current projections estimate 13 named storms, including several major hurricanes that could directly impact the United States. These storms bring massive amounts of rainfall, storm surges, increased lightning activity and, most importantly, damaging winds that can sever the electric power supply to the existing grid.

For wastewater collection systems, the risk extends far beyond power outages. Flooding, equipment failures, damage to instruments and controls and overwhelming inflow and infiltration can quickly compromise lift station performance. When these systems fail, municipal utilities not only face operational disruptions but also regulatory fines/penalties, public health risks and environmental damage.

The Critical Role of Lift Station Reliability

ALift stations are critical control points within wastewater collection systems—particularly in flat or low-lying areas where gravity conveyance is not feasible. Under normal conditions, electric-driven submersible pumps efficiently move wastewater from these lift stations to treatment facilities.

During severe weather, however, multiple failure points can occur simultaneously, as shown in Image 1. Because these risks often occur at the same time, emergency preparedness must address system-wide resilience rather than isolated vulnerabilities.

| IMAGE 1: Multiple failure points can occur simultaneously during severe weather events. (Image courtesy of Thompson Pump & Manufacturing Company)

Defining True Redundancy

Resilience in lift stations is achieved through functional redundancy, the use of independent systems capable of maintaining operations when primary components fail.

This goes beyond simply adding backup power. Effective redundancy reduces system dependencies, anticipates realistic failure scenarios and integrates both technical and operational safeguards to ensure continuity of service.

Redundancy as a Design Strategy With Diesel-Driven Systems

One of the most critical considerations in lift station design is maintaining pumping capability during a power loss or system disruption through an alternate energy source. Diesel engine-driven systems are widely used in emergency applications due to several key characteristics:

  • Emergency standby diesel engines require no after-treatment to comply with emergency stationary emission standards.
  • These types of engines have been used frequently in heavy equipment for years, and most field service technicians have a basic working knowledge of maintenance requirements. Fewer components reduce complexity and potential failure points.
  • Aftermarket support infrastructure for diesel engine components is diverse, with locations to support most domestic municipalities.
  • Automatic start/stop control panels allow engines to operate intermittently, resulting in lower fuel consumption, less on-site fuel storage required and a smaller footprint.
  • Automatic power transferring devices are not required for intermittent bypass pump operations.
  • The diesel engine electronic control unit (ECU) automatically adjusts engine speed based on the water level, which reduces diesel fuel consumption.

These attributes make diesel-driven systems well-suited for maintaining performance during emergency conditions.

Limitations of Portable Emergency Response

Historically, many utilities have relied on portable pumps and generators to provide temporary backup during emergencies. While effective in planned scenarios, these approaches often introduce logistical challenges during severe weather, including:

  • Deployment delays due to limited resource availability
  • Safety concerns for staff during mobilization and setup in hazardous conditions
  • Increased fuel coordination and fuel consumption
  • Additional portable accessories required (must be in good working order)
  • Additional staff required for setup; greater potential for setup or operational errors

In widespread events, these constraints can reduce response effectiveness.

Stationary Bypass Pumps vs. Generator Systems

HGenerator backup systems rely on multiple interconnected components, including automatic transfer switches (ATS), electrical connections and existing control panels. Each of these elements must function correctly during an emergency, increasing the risk of cascading failures. They also only address power loss. They do not mitigate risks associated with mechanical failure, debris loading or system overload—factors that frequently contribute to SSOs during severe weather.

In contrast, stationary bypass pumps operate as self-contained units independent of the existing electrical system. This eliminates several common failure points and ensures pumping capability is maintained regardless of grid conditions or electrical system performance.

The distinction between these two options becomes critical during severe weather events, when the likelihood of cascading failures increases. These characteristics make diesel engine-driven bypass pumps particularly well-suited for an emergency scenario.


Stationary bypass systems reduce reliance on external resources.


Stationary Bypass Pumps

Stationary bypass pumping systems are an alternative that integrates full redundancy directly into lift station design. Permanently installed and ready for immediate operation, these systems can eliminate many uncertainties associated with emergency response.

These systems are designed to:

  • Operate automatically in response to rising water levels in the wet well
  • Function independently of the electrical grid, so no ATS is required
  • Handle solids and debris commonly found in wastewater
  • Run intermittently and unattended for extended periods during emergency events
  • Consume less fuel due to intermittent operation with less on-site fuel storage
  • Handle a wide range of flow rates at various pressures with variable speed control
  • Communicate with supervisory control and data acquisition (SCADA) systems or provide redundant wireless communication/control

By removing the need for manual mobilization, setup and intervention, stationary bypass systems can reduce response time and improve reliability in a collection system.

Reducing Risk & Long-Term Costs

While portable systems remain useful for planned maintenance, permanent installations provide a high level of preparedness for emergency events.

Stationary bypass systems reduce reliance on external resources and minimize labor demands during critical periods. Operators can focus on monitoring and system management rather than equipment deployment.

Over time, these operational advantages often translate into financial benefits. Avoiding even a single overflow event can offset the initial investment by reducing emergency response costs, environmental remediation and regulatory penalties.

Preparing for the Season Ahead

Emergency preparedness is not defined by how many storms occur but by how systems perform when they do. As climate variability increases and infrastructure continues to age, the need for proactive, resilience-focused planning becomes more urgent. Utilities that prioritize functional redundancy, reduce system dependencies and invest in permanent backup solutions are better positioned to protect public health, maintain regulatory compliance and ensure continuity of service.

Resilience is not built in the moment of crisis—it is built well before it arrives.


For more than 22 years, David Perry has worked at Thompson Pump & Manufacturing Company in various positions. Perry was promoted to municipal sales manager in 2014, and he oversees all government business activity for the U.S. and Canada. For more information, visit thompsonpump.com.