COVER SERIES | Vibration & Alignment
A Smarter Approach to Pump Vibration
A three-step pump condition monitoring framework.
Jacob Lazzarotto | Xylem
| IMAGE 1: Working on inspecting a pump (Photo credit: Adobe Stock)
A high-vibration alarm can quickly get a maintenance team’s attention. The challenge is determining what that reading actually means.
It may be tempting to attribute elevated vibration to a familiar cause such as shaft misalignment, bearing wear or imbalance and immediately schedule repairs. However, it is crucial to remember that an alarm is only identifying a condition, not a cause. A change in vibration may reflect deterioration within the pump, a change in system operation or both.
Even the most familiar vibration signatures require context. For example, parallel shaft misalignment is often associated with a second harmonic (2x) of shaft running frequency. However, mechanical looseness can also produce a strong 2x component. Without further context, hours may be spent realigning a motor only for the issue to persist because the true problem was mechanical looseness that emerged after a bearing housing was remachined during the previous pump maintenance.
A smarter approach follows three basic steps: establish what healthy operation looks like (a baseline), monitor changes over time under comparable operating conditions and investigate the underlying cause when a meaningful change occurs.
1. Establish a Meaningful Baseline
Effective vibration monitoring starts before a problem develops. Baseline measurements should be collected after equipment has been properly installed and while it is operating under known conditions. The objective is to establish a reliable picture of healthy equipment behavior for future comparisons and informed alarm settings.
A meaningful baseline also depends on a mechanically sound installation. Shaft alignment, soft foot, mounting conditions, base integrity and piping strain should be addressed before initial measurements are recorded. Otherwise, installation problems may become embedded within the baseline and be mistaken for normal behavior. Alignment should also be reverified after startup to account for changes in operating temperature and loading.
A useful baseline pairs vibration measurements with time-stamped operating data including shaft speed, head, flow and, if possible, power. Record the pump configuration and pumped fluid type. Maintain consistent sensor locations, measurement directions, mounting methods and measurement settings. For pumps operating under variable conditions, collect data across the expected operating range. A single reading at one duty point cannot adequately represent healthy operation in another.
2. Trend Monitoring, Absolute Thresholds & Alarms
When monitoring changes in the pump’s health, the goal is to distinguish changes associated with operating duty from pump-motor degradation or failure.
Therefore, when establishing alarm settings, it is crucial to account for the system’s influence on vibration. Changes in speed and flow can affect vibration even when the pump’s mechanical condition is unchanged. American National Standards Institute (ANSI)/Hydraulic Institute (HI) 9.6.4-2022 recognizes this operating-point dependence by specifying a 30% increase in the allowable overall root mean square (RMS) vibration velocity values for between-bearings and overhung pumps operating outside the preferred operating region (POR) but within the allowable operating region (AOR).
These criteria apply when the pump and motor are in new condition. Even though an increase in vibration outside the POR may be technically acceptable, it should not automatically be dismissed as harmless. Unintended operation away from the expected duty point warrants investigation, particularly when it moves the pump outside its preferred operating region.
Monitoring thresholds should consider both the standard limits and deviations from healthy behavior under comparable operating conditions. Note that the 30% rule applies to the standard’s specified allowable values rather than an automatic increase to a measured baseline. For baseline-based thresholds, ANSI/HI 9.6.5-2022 provides guidance. For example, an unfiltered RMS velocity measurement of 130% of the baseline value would be a reasonable alert threshold.
Combining absolute limits with baseline trend monitoring can reveal developing changes before a preset alarm threshold is reached. When an alarm does occur, the recorded history provides context for investigating its cause. Consider two pumps with similar current RMS vibration levels, both below the applicable allowable limit. One has remained close to its established baseline for months. The other has shown a sustained increase over several weeks. Using the smarter approach to pump vibration, the second pump warrants closer review because its vibration is departing from its established behavior, even though it remains below the limit.
Recording flow, head, speed and other operating conditions alongside vibration data helps determine whether readings are comparable with the baseline. A sustained increase under comparable conditions strengthens the case for investigating pump, motor or baseplate deterioration. If the increase coincides with a change in operating point, system conditions may be contributing. These relationships guide the investigation but do not establish the cause on their own.
Rather than reacting to every fluctuation, maintenance teams should focus on meaningful changes from established operating patterns and use those changes to determine when further investigation is warranted.
3. Diagnose the Source
Once a meaningful vibration change is verified, investigate mechanical, hydraulic and structural causes together. These categories can interact. For example, a system change may increase hydraulic forces, while a weakened support amplifies the resulting vibration.
Start by comparing time-stamped flow, speed, head and suction pressure with the vibration trend. Does the increase follow a change in operating conditions, or does it persist at a previously established duty point? Does vibration stabilize when conditions stabilize? These relationships help direct the investigation.
For example, increased vibration accompanying reduced suction pressure warrants checking suction restrictions and available net positive suction head for possible cavitation. Unexpectedly high flow warrants reviewing valve positions, demand and control settings. Such correlations would support a hydraulic or system-related explanation, but they do not establish the cause or rule out concurrent equipment damage.
If vibration remains elevated under comparable operating conditions, examine the pump, motor and supporting structure. A sound installation at commissioning does not exclude later loosening, foundation deterioration, piping strain or soft foot. Vibration concentrated within a narrow speed range may also warrant investigation of structural resonance.
Frequency analysis helps narrow the possibilities. To better understand what is inducing a vibration, a fast Fourier transform (FFT) spectrum is needed. The FFT spectrum graph shows what frequencies make up any given signal and which frequency contributes most to the vibration being measured.
Comparing these frequency peaks against the shaft running speed and its known component frequencies provides diagnostic clues. ANSI/HI 9.6.5-2022 or International Organization of Standardization (ISO) 13373-3:2015 standards provide condition monitoring and diagnostic guidance, while bearing manufacturers’ diagnostic guides illustrate common spectral signatures. Use these references to develop and test different explanations.
Prior to beginning any corrective work, seek confirming evidence. If coupling misalignment is suspected, verify it using laser alignment or dial indicators. With equipment stopped and isolated, motor soft foot and mounting distortion can be checked prior to realignment. If bearing damage is suspected, some envelope analysis may be required. For a suspected bent shaft, it would be prudent to perform an inspection for runout and visual damage. Any repairs or adjustments should address the confirmed cause and be validated with follow-up trend analysis.
Jacob Lazzarotto is lead engineer for Xylem’s Bell & Gossett new product development team. He has been with Xylem for almost eight years. For more information, visit xylem.com.