HI Pump FAQs
Vibration in Horizontal & Vertical Pumps & Do VFDs Always Save Energy?
HYDRAULIC INSTITUTE

| IMAGE 1: Illustrative fast Fourier transform (FFT) for an 1,800 rotations per minute (rpm) pump, showing a dominant peak at 1X running speed (30 Hz), which unbalance contributes to (Images courtesy of the Hydraulic Institute)
QUESTION
How does vibration caused by unbalance differ between horizontal and vertical pumps?
Unbalance occurs when the mass center of a rotating component does not coincide with its rotational centerline. The resulting centrifugal force acts once per revolution, which typically produces vibration at a frequency equivalent to the rotational speed. This is referred to as 1 times running speed or 1X. Image 1 illustrates a plot of vibration amplitude versus frequency, noting that 1X occurs at 30 hertz (Hz) with smaller amplitude harmonics at 2X and 3X.
To limit residual unbalance and associated vibration, pump impellers are balanced to International Organization of Standardization (ISO) balance grades. This is like a car mechanic adding balance weights on car wheels to limit residual unbalance, although balancing pump impellers typically involves removing material at specific locations instead of adding it. Additionally, the connection of the impeller to the pump shaft has tolerances to limit the installation looseness that would cause the mass to be off center.
Relative to horizontal and vertical pumps, unbalance is the same physical concept, but the pump design and dynamics of the structure will result in different vibration behavior. The description of all the ways the vibration could be different is long and design, application and installation specific, but the vibration will still occur at 1X. Areas where the vibration characteristics will vary are the amplitude, direction and phase relationship. For example, a horizontal overhung impeller will have different unbalance vibration characteristics than a horizontal pump with impellers mounted between bearings.
A key distinction for vertical pumps is that the rotor is oriented vertically and may consist of a discharge head that a vertical motor is mounted on, a long shafting system with multiple line shaft bearings and one or multiple impellers mounted below grade. As a result, the vibration is typically measured at the top of the discharge head and other above-ground locations. The vibration measured at these locations is often used to deduce what is occurring below ground but can differ significantly from the actual vibration occurring lower in the pump. In addition, the dynamic behavior of the structure, column, foundation and piping can influence the measured vibration. Resonance effects may also be more significant in some vertical pump installations.
To determine if vibration is actually related to unbalance being too high normally requires a detailed analysis or ongoing condition monitoring that tracks the fault progression in a consistent way.
Analysts commonly use American National Standards Institute (ANSI)/Hydraulic Institute (HI) 9.6.4 Rotodynamic Pumps for Vibration Measurement and Allowable Values for measurement procedures, locations and allowable vibration levels for rotodynamic pumps, ANSI/HI 9.6.5 Rotodynamic Pumps Guideline for Condition Monitoring for guidelines on ongoing monitoring of vibration and ANSI/HI 9.6.8 Rotodynamic Pumps Guideline for Dynamics of Pumping Machinery for details on types and levels of dynamic analysis that can be done to evaluate and limit resonant amplification of vibration, including vibration related to unbalance. For additional information on this topic, refer to these standards and guidelines at pumps.org.

| IMAGE 2: HI Data Tool pump and system curve demonstrator using control valve to lower flow rate. Green control valve head is a power loss that could be avoided by reducing pump speed.

| IMAGE 3: HI Data Tool pump and system curve demonstrator using reduced speed, lower flow rate and eliminating the head loss across the control valve
QUESTION
Do VFDs save energy in every pumping application?
The short answer is no, not for every pumping application because there are instances where a variable frequency drive (VFD) could be included but not actually set up and programmed to change the speed of the pump to maintain a system set point. However, the answer is yes for the vast majority of cases where a VFD is used to control the speed of a pump to meet a specific system set point. Even if a VFD is used in a pump system that does not require varying the pump’s speed, VFDs can often save energy by “trimming” the performance to match the actual system requirements instead of throttling a valve or operating the system at a higher flow rate than required.
For example, Image 2 shows a pump system where the pump is oversized, the flow rate would be more than required and a control valve is used to throttle the flow. This results in energy loss (head) across the valve so that operating point is a lower flow rate and higher head. The energy loss is represented by the green control valve head. The greater the difference between the pump curve and system curve at the operating point flow rate correlates to greater potential energy savings if pump speed were reduced instead of throttling the control valve. Image 3 illustrates the optimized configuration where the pump speed is reduced instead of throttling the control valve to eliminate the associated energy loss.
The key takeaway is that a pump system that includes a VFD that is set up properly and used to match system requirements will almost always save energy. The amount of savings depends on the system characteristics and operating requirements. To learn more about pump system operation, refer to the free HI Data Tool at datatool.pumps.org.

HI Pump FAQs® is produced by the Hydraulic Institute as a service to pump users, contractors, distributors, reps and OEMs.