Sealing Sense

Gasketed Flanged Joints & Pump Reliability

Better gasket reliability leads to better pump reliability and vice versa.

Anita Bausman & Moody Awad | Fluid Sealing Association members, VSP Technologies

| IMAGE 1: A full face flange (Images courtesy of VSP Technologies)

| IMAGE 2: A raised face flange

| IMAGE 3: RF flange with a supporting spacer ring to join against an FF flange

Gasketed flanged joints can both impact pump reliability and be impacted by an unreliable pump. A poorly installed pump may have vibration, poor piping flange alignment or flow turbulence issues that could cause a gasketed joint to leak. Conversely, a poorly selected gasket can cause mechanical and hydraulic pump reliability problems.

Pump casings are often made with cast metal, while piping flanges are routinely made with forgings. Castings can be brittle relative to many forgings. As a result, cast flanges are typically flat face (FF) so there is no raised face to function as a fulcrum or pivot that the flange might bend around as the assembly bolts are tightened. Brittle flanges do not bend; they crack. The forged piping flange, on the other hand, is typically much more ductile and can be a raised face (RF) flange.

Images 1 and 2 demonstrate the difference. Image 1 is a cutaway drawing of an FF flange, which is completely flat across its whole face. The sealing surface is the entire FF flange surface. Image 2 is the same view of an RF flange. Note the raised ring (face) around the inner part of the flange. The much smaller sealing surface is just the raised face area. The flange area from the raised face outer diameter (OD) to the flange OD does not take part in the sealing and does not contribute to the bolt assembly load. The smaller face area is the advantage of RF flanges. These flanges are American Society of Mechanical Engineers (ASME) B16.5 Class 150 NPS 3 sizes, also referred to as 3x150.

Gasket selection to mate the ductile (bendable) RF piping flange to the brittle (not bendable) FF pump flange requires that the raised face OD not act as a fulcrum that might crack the more brittle FF flange. One way to achieve this is to add a spacer or support ring equal in thickness to the raised face height. The support ring covers the flange area from the raised face OD to the flange OD and includes the same bolt hole pattern as the RF flange. The spacer ring can be made of any reasonably stiff material. Metal could be used, but a metal ring is expensive and has a long delivery time. A simpler ring can be cut from any relatively stiff gasket material. The same shops that make the sealing gasket can make the spacer ring; the spacer should be harder/stiffer than the sealing gasket. This configuration helps the RF flange act more as an FF flange. See Image 3 for an example of a spacer ring on the RF flange from Image 2. The normal gasket for the FF flange is used to seal the joint.

FF pump flanges resist bending but require compressing a large gasket area. Required gasket stress depends on bolt load and gasket area. The 3x150 joint is often under-bolted and may not seat even ring gaskets reliably. Full-face gaskets are often limited to soft elastomers requiring about 500 pounds per square inch (psi) seating stress. Harder materials, such as polytetrafluoroethylene (PTFE) or compressed nonasbestos fiber, typically require 3,000 to 5,000 psi and are difficult to seat reliably in this configuration.

Spiral wound gaskets, in addition to the high seating stress requirement (10,000 psi and up), have the added problem of creating a pivot point and can be problematic on cast flanges. Kammprofile-style gaskets seat in the same range as the sheet gaskets but would also create a pivot point.

One innovation in sheet-based gasket designs for FF joints is to use a reduced area gasket that maintains gasket area around the bolts (supporting the FF flange against rotation/bending) while eliminating gasket material between the bolts. The reduced gasket area reduces the required assembly load from the bolts. Image 4 shows the original FF gasket geometry in an elastomer that might work on this joint if the elastomer is chemically compatible with the process and the process temperature is low enough. Image 5 shows a reduced area gasket in a harder, expanded PTFE (ePTFE) material. The gasket area reduction and thus the required assembly bolt load reduction are significant (Image 6).

The gaskets in Images 4 and 5 are sealing gasket options. The supporting spacer ring shown in Image 3, while made of a gasket material (here, a hard, silica-filled PTFE), is not functioning as a gasket—it is not sealing the joint. The stacked joint is shown in Image 7 with an FF elastomer and Image 8 with a reduced area ePTFE gasket. Both use the red spacer ring, so the RF flange does not cause bending on the FF flange.

| IMAGE 4: Full face gasket on FF flange

| IMAGE 5: Reduced area gasket on FF flange

| IMAGE 6: Full face and reduced area gaskets on the FF flange, demonstrating a significant required bolt load reduction with the second option

| IMAGE 7: RF flange with spacer ring to FF flange joint showing an FF elastomer gasket

| IMAGE 8: RF flange with spacer ring to FF flange joint showing a harder reduced area gasket

The previous discussion involved selecting gaskets that are mechanically compatible with a pump’s flanges. Incorrect gasket selection can also cause hydraulic problems for a pump. PTFE gaskets are wonderful for chemical compatibility, but they are notorious for creep relaxation, particularly as the process temperature increases. As an example, Image 9 shows a commercial grade, 25% glass-filled PTFE that was compressed for an EN-13555 leakage test. An uncompressed gasket is shown on the right. The original dimensions were 1.925 x 3,618 inches and 0.130 inches thick. The compressed gasket is shown on the left. After testing, the commercial glass-filled PTFE gasket experienced substantial deformation. The ID decreased by more than 0.5 inches and thickness was reduced by roughly half. The resulting flow restriction can increase turbulence, cavitation risk and vibration, particularly on pump suction lines. Continued creep relaxation can unload bolts, increase leakage potential and create drainage issues in horizontal piping.

Modern PTFE formulations provide better performance. Under the same EN-13555 test conditions, the ePTFE gasket showed only minor ID reduction and far less flow intrusion. Although it compresses during initial loading, it is considerably more thermally stable and resistant to creep relaxation than commercial glass-filled PTFE. When specifying PTFE, engineers should evaluate mechanical performance as carefully as chemical compatibility.

Pumps can negatively impact gasket performance and reliability. Pumps that are poorly installed negatively impact joint integrity and contribute to gasket leakage. A solid base helps to absorb vibrations and maintain pump alignment. Suction piping a commercial size larger than the pump suction and with a straight run into the pump for 3 to 10 pipe diameters improves hydraulic flow into the pump for smoother operation.

| IMAGE 9: Commercial grade, 25% glass-filled PTFE gasket before (right) and after (left) an EN-13555 leakage test at 100 megapascal (MPa) and 10 bar, ambient temperature

| IMAGE 10: ePTFE gasket before (right) and after (left) an EN-13555 leakage test at 100 MPa and 10 bar, ambient temperature

Suction piping errors have more of an impact than discharge errors. Consider eccentric reducers on the suction side to eliminate potential air pockets, etc. Discharge piping also benefits from a straight run of 3 to 5 pipe diameters from the pump flange to the first valve, elbow, etc. Discharge piping benefits from concentric reducers. Small details like these help the pump run smoother with less vibration. Less vibration improves gasket reliability as well as the pump’s mechanical seal and bearings reliability.

In addition to the design, proper execution of the installation is critical to both pump and gasketed joint reliability. Good pump alignment reduces vibration, improves gasket seating and reduces potentially damaging external loads on the pump. ASME PCC-1 Appendix E offers guidance on piping installation tolerances so joint assembly loads go to seating and sealing the gasket instead of just pulling the joint more or less together. Attention to these installation details will also minimize external loads on the pump flanges.

Pump reliability and gasketed joint reliability go hand in hand. Selecting the right gasket can be critical both mechanically and hydraulically.

For the extended version of this article, visit pumpsandsystems.com/article/gasketed-flanged-joints-pump-reliability.


Anita Bausman is a senior applications engineer at VSP Technologies.

Moody Awad serves as an applications engineer at VSP Technologies. For more information, visit vsptechnologies.com.

In This Issue

Table of Contents
From the Editor
News
On the Curve
Columns
Special Section
Cover Series Vibration & Alignment
More Topics
Departments
Marketplace
Ad Index
Back Page
Meet Our Team
Magazine Archive

The Leading Resource for Pump Users Worldwide

Subscribe Today!

Share With Your Network: