SPECIAL SECTION | Motors & Drives
Prevent Energy Waste With VFDs
A look at the advantages VFDs can provide.
Abel Cavazos & Jose Simpson | ABB

| IMAGE 1: An electric motor paired with a variable frequency drive provides controlled power for pump operations. (Image courtesy of ABB)
For decades, pumping systems have utilized valves to mechanically regulate flow and pressure. While this approach has proven functional, it can come with a hidden cost—wasted energy. One option to combat this is the pairing of inverter-duty motors with variable frequency drives (VFDs). This combination can eliminate the inefficiencies of throttling and deliver operational benefits that extend beyond energy savings. By understanding how this motor-VFD partnership can improve pump engineering, operators and engineers can make informed decisions that enhance efficiency, reliability and sustainability.
Traditional Throttling
Mechanical throttling restricts flow in a system that is attempting to pump as much fluid as it was designed for, wasting excess energy. Consider a pump operating at full speed but throttled down to only move 50% of its rated capacity.
Traditional throttling can waste energy and costs associated with unused capacity of the pump. The affinity laws—the mathematical model of pump behavior—reveal just how wasteful this approach can be. Change in flow varies proportionally with change in pump speed, whereas power consumption varies with the cube of the change in speed. This means that reducing the pump speed by half can cut energy consumption to just one-eighth of its full speed value.
Beyond energy loss, valve throttling does not improve wear and maintenance costs versus operating at full flow. It generates friction and heat that can stress multiple components in the pump train, such as motor insulation, seals and other components.
Furthermore, the bearings are still operated at full speed, which does not improve bearing life. Finally, unmonitored pressure fluctuations caused by throttling can introduce water hammer into the system, damaging piping and shortening equipment life. These potential issues can cause major issues in modern applications where efficiency and reliability are paramount.
VFDs & Inverter-Duty Motors
Instead of operating pumps constantly at full speed and restricting flow processes, VFDs paired with inverter-duty motors throttle flow by dynamically adjusting motor speed to match real-time load demands. This approach harnesses the affinity laws to deliver significant energy reductions. For example, operating a pump at 80% speed could reduce energy consumption to 51% compared to a pump system that is operating at full speed but throttled to 80% flow.
VFDs also use less energy when starting pumps. VFDs softly accelerate the motor with sufficient torque without requiring excess current. This avoids the heavy electrical draw normally required to start a motor, which stresses both the motor and the grid. It also reduces electrical disturbances that can affect other equipment in the vicinity, especially in weak grids, lowering the risk of penalties from electric providers for grid interruptions. For systems with higher friction losses, savings approach the theoretical maximum predicted by the affinity laws. Even in systems with static heads, such as lift stations or boiler feed pumps, the benefits remain substantial.
There are also considerable mechanical benefits. VFD-controlled acceleration eliminates the mechanical shocks and high torsional torques in the motor and pump that damage bearings, shafts, couplings, seals, impellers and piping. Water hammer is minimized when pressure changes occur gradually rather than instantaneously. The result is extended equipment life, reduced maintenance costs, higher availability and lower operational downtime.
Process Control & System Flexibility
Beyond efficiency, VFDs can also unlock control capabilities. Precise flow and pressure regulation via closed-loop control can eliminate the need for bypass systems and throttling valves. Pumps driven by VFDs can respond rapidly to changing process load demands, improving operational efficiency and product quality. Advanced control modes enable features previously unavailable with fixed-speed systems, such as level- and pressure-based automation, sleep-wake functionality to reduce standby power consumption and resonance avoidance algorithms that prevent excitation of pump and piping resonances.
VFDs can integrate into a building management system and/or a supervisory control and data acquisition (SCADA) system through an industrial protocol, such as Modbus, Ethernet/IP enable real-time monitoring of critical parameters, including motor speed, current draw, power consumption and detailed fault history. This visibility allows operators to switch maintenance from reactive to predictive. Operators can identify problems before they become critical, schedule maintenance strategically and optimize system performance continuously.
Integrated Motor Protection
Traditional motor protection relies on instrumentation such as current transformers and fixed relays calibrated for 60 hertz (Hz) operation. At variable frequencies, these relays can become unreliable, creating a dilemma: Operators must either risk nuisance trips that disrupt operations or miss genuine faults that damage equipment. VFDs can help solve this problem through integrated, intelligent protection algorithms that adapt to changing speeds and operating conditions.
VFD-based protection monitors multiple fault conditions that fixed relays cannot reliably detect, such as stall conditions, locked rotor situations, ground faults, phase loss and voltage anomalies. Thermal overload algorithms incorporate motor cooling models that account for reduced cooling at reduced speeds, ensuring accurate thermal management across the entire operating range. Integration of winding and bearing temperature sensors enables detection of heat-related degradation before catastrophic failure occurs. Dry-run and loss-of-prime detection compares actual motor load against speed-dependent reference curves, catching operational anomalies that would be invisible to traditional protective devices.
Economic & Practical Considerations
The return on investment for VFD-equipped systems depends on several factors. Payback periods are shortest in applications with long operating hours and extended operation at reduced speeds—the scenarios where cube-law energy savings provide maximum benefit. Friction-dominated systems yield the fullest energy savings. Applications with high static head still benefit, though savings are more modest due to the necessity of maintaining minimum flow velocities.
It is worth noting that VFDs introduce minor system losses as an additional element in the lineup. These losses are typically outweighed by the energy savings achieved during partial-load operation, which represents most pump duty cycles in real-world applications.
System design must address power quality considerations, particularly in facilities with multiple VFDs or stringent grid requirements. Modern solutions (multipulse transformers and active front-end converters) can effectively manage harmonic distortion and maintain Institute of Electrical and Electronics Engineers (IEEE) 519 compliance, ensuring grid stability and minimizing impact on facility power factors.
The Path Forward
The combination of inverter-duty motors and VFDs can offer energy savings, enhanced process control precision, extended equipment life, integrated motor protection and operational flexibility. As energy costs rise, sustainability and efficiency are not merely advantageous; they are essential.
Abel Cavazos is project management lead for motors and generators in the United States, supporting the business across the North American market. With more than 17 years of experience in motors and generators, Cavazos has held roles in field service and technical sales support, working with OEM and EPC customers.
Jose Simpson is head of product management for drives in the United States, where he leads portfolio market strategy and execution. He brings 15 years of commercial and technical experience with variable frequency drives and motors. He also serves as vice-chair of the Institute of Electrical and Electronics Engineers (IEEE) Industry Applications Society (IAS) Mining Industry Committee, which meets annually alongside IEEE IAS PCIC.